150mm (6″) ID Pumice Liner

150mm is the 6 inch nominal size. The liner is metric. It is the usual pumice flue for a domestic stove with a 125mm or 150mm outlet.

18  Products


Which 150mm liner parts do I need?

Specification: 150mm internal diameter, 200mm outside diameter, 600mm section length, approx. 8kg per section (Isokern price list). Certified by Schiedel to EN 1857 (T600 N2 D 3 G). Suitable for all fuel types, but not for condensing appliances.

Volcanic pumice, rebated, light enough to handle on a scaffold and easy to cut. Joints are lip glue, with LECA in the void around the liner. Use the liner calculator for the height and the parts. Open fires normally start at 200mm.

150mm rebated liner, 600mm

The flue section; joints sealed with lip glue.

View

Liner support block

Base of the liner run at the stove connection.

View

Support plate

Used with the support block.

View

Stainless steel adaptor 150mm

Connects the stove pipe to the liner.

View

Increaser adaptor 125mm to 150mm

For an appliance with a 125mm outlet.

View

15°, 30° and 45° bends

Offsets: up to two offsets (four bends), no more than 45° from vertical.

View

45° and 90° T liners

Rebated T sections for a rear or side connection.

View

Rebated access block

Access section in the liner run.

View

Steel collar

Required with lip glue on any cut joint.

View

Lip glue 5kg

Seals every pumice-to-pumice joint.

View

LECA 50L

Minimum 15mm insulation around the liner.

View

Installation points from Schiedel

  • Install the liners socket uppermost and seal every joint with lip glue, about 2mm thick, removing any excess.
  • Surround the liners with at least 100mm of masonry, with a minimum 15mm of LECA mixed 20:1 with OPC cement in between.
  • Support any bends and backfill them with the LECA mix; liners can be cut between bends to reach the offset you need.
  • Keep combustible materials 200mm from the inner surface of the liner, or 40mm from the outside of the masonry chimney.
  • Terminate the chimney at the correct height under Approved Document J, then test it and fix the chimney notice plate in the dwelling.

Using the chimney

Schiedel advises leaving a new chimney for at least 72 hours, then lighting only small fires for the first week. Sweep at least twice a year with a 150mm medium-density polypropylene brush; never use a steel brush on a pumice flue. Burn approved fuels or dry, seasoned wood.

Building to a standard height? A 150mm liner pack brings the liners, stove connection, lip glue, LECA and notice plate together. Read more in how Isokern pumice flue liners work.

150mm pumice liner parts FAQs

What size stove suits a 150mm liner?

The flue size is set by the appliance manufacturer and Approved Document J. 150mm is the usual size for a domestic stove with a 125mm or 150mm outlet.

What else do I need with 150mm liners?

Lip glue for every joint, LECA for the insulation, a support block, support plate and adaptor at the stove, any bends and a chimney notice plate. A 150mm liner pack brings most of these together.

Can I cut a pumice liner?

Yes. Pumice is easy to cut, and liners can be cut between bends. Any cut joint needs a steel collar as well as lip glue.

Need help choosing your 150mm pumice liner parts?

Speak to our Isokern team on 0113 322 5187 or email [email protected]. We can check sizes, flue requirements and what to order.