175mm (7″) ID Pumice Liner Pack

The 175mm pack is the 7 inch stove kit, for an appliance outlet up to 175mm.

12  Products


Which 175mm liner pack height do I need?

In the pack: rebated pumice liners, support block, 175mm stainless adaptor, lip glue, LECA for the minimum void, and a notice plate. Order extra LECA if the chimney void is larger than the minimum. Bends are separate.

The 175mm (7 inch) pack is put together by Isokernshop from genuine Schiedel Isokern components. Every height includes the stove connection: a 175mm liner support block, a support plate for 175mm and 200mm, and a 175mm stainless steel adaptor, plus a chimney notice plate. If the appliance outlet is smaller, a reducing adaptor can be chosen on the product page.

175mm 4.8m pack

4.8m, 8 175mm liners (600mm).LECA 50L bags: 8; Lip glue 5kg bags: 1

View

175mm 5.4m pack

5.4m, 9 175mm liners (600mm).LECA 50L bags: 9; Lip glue 5kg bags: 1

View

175mm 6.0m pack

6.0m, 10 175mm liners (600mm).LECA 50L bags: 10; Lip glue 5kg bags: 1

View

175mm 6.6m pack

6.6m, 11 175mm liners (600mm).LECA 50L bags: 11; Lip glue 5kg bags: 1

View

175mm 7.2m pack

7.2m, 12 175mm liners (600mm).LECA 50L bags: 12; Lip glue 5kg bags: 2

View

175mm 7.8m pack

7.8m, 13 175mm liners (600mm).LECA 50L bags: 13; Lip glue 5kg bags: 2

View

175mm 8.4m pack

8.4m, 14 175mm liners (600mm).LECA 50L bags: 14; Lip glue 5kg bags: 2

View

175mm 9.0m pack

9.0m, 15 175mm liners (600mm).LECA 50L bags: 15; Lip glue 5kg bags: 2

View

175mm packs compared by height

Chimney height175mm liners (600mm)LECA 50L bagsLip glue 5kg bagsShop
4.8m881175mm 4.8m pack
5.4m991175mm 5.4m pack
6.0m10101175mm 6.0m pack
6.6m11111175mm 6.6m pack
7.2m12122175mm 7.2m pack
7.8m13132175mm 7.8m pack
8.4m14142175mm 8.4m pack
9.0m15152175mm 9.0m pack

Heights rise in 0.6m steps, one 600mm liner at a time. The LECA allowance is based on an internal chimney void of 350mm x 350mm; a larger void needs more, so check with the liner calculator.

About the 175mm liner

Each Isokern 175mm liner has a 235mm outside diameter, is 600mm long and weighs about 11kg (Isokern price list). Schiedel certifies the liners to EN 1857 (T600 N2 D 3 G). They suit all fuel types, but not condensing appliances, and can be used for a new-build chimney or to reline an existing masonry chimney. The flue size is set by your appliance, so follow the appliance manufacturer's instructions and Approved Document J.

Parts for a 175mm chimney

PartWhat it is forShop
Liner support blockBase of the liner run at the stove connection (included in the pack)View
Support plate for 175mm and 200mmUsed with the support block (included in the pack)View
Stainless steel adaptor 175mmConnects the stove pipe to the liner (included in the pack)View
Increaser adaptor 150mm to 175mmFor an appliance with a 150mm outletView
45° rebated T linerRebated T section for a rear or side connectionView
T liner adaptor 175mmConnects a stove pipe into the T linerView
15°, 30° and 45° bendsOffsets in the flue routeView
Steel collar 175mmRequired with lip glue on any cut jointView

Installation notes from Schiedel

  • Install the liners socket uppermost and seal every joint with lip glue, about 2mm thick, removing any excess so the flue stays smooth.
  • Surround the liners with at least 100mm of brick, block or stone, with a minimum 15mm of LECA between liner and masonry, mixed 20 parts to 1 part OPC cement.
  • Keep the route as straight as possible: up to two offsets (four bends) at no more than 45° from vertical, supported and backfilled with the LECA mix. Choose from the 15°, 30° and 45° 175mm bends; liners can be cut between bends, and a cut joint needs a steel collar as well as lip glue.
  • Keep combustible materials 200mm from the inner surface of the liner, or 40mm from the outside of the masonry.
  • Terminate the chimney at the correct height under Approved Document J, test it, and fix the completed notice plate in the dwelling. Leave it at least 72 hours before use, then light only small fires for the first week.

Schiedel allows the stack to be finished by flaunching (1:3 cement to sharp sand) around the liner itself or around a suitable chimney pot; we do not list a 175mm pot, so see the chimney pots page for the sizes available. Approved rain caps help keep water out of the flue.

Need a different height? Single 175mm liners are sold separately. Compare every size on the pumice liner packs page, or read how Isokern pumice flue liners work.

175mm liner pack FAQs

What is included in the 175mm pack?

Rebated 175mm pumice liners, a liner support block, a support plate, a 175mm stainless steel adaptor, lip glue, LECA for the minimum void and a chimney notice plate. Quantities by height are in the table above.

My chimney is taller than 9.0m. What should I order?

Choose the 9.0m pack and add single 175mm liners, with extra lip glue and LECA as needed. Liners in this size are 600mm long.

Are bends included?

No. 175mm bends, steel collars and chimney pots are ordered separately. Schiedel allows up to two offsets (four bends) per chimney, at no more than 45° from vertical.

Do I need extra LECA?

The pack allowance is based on an internal chimney void of 350mm x 350mm. A larger void needs more LECA, so check with the liner calculator.

Will a 175mm pack suit a stove with a 150mm outlet?

Yes. A 150mm to 175mm increaser adaptor can be chosen on the product page instead of the straight 175mm adaptor.

Need help choosing your 175mm liner pack?

Speak to our Isokern team on 0113 322 5187 or email [email protected]. We can check sizes, flue requirements and what to order.

Isokern is made by Schiedel; we are not the manufacturer.