Pumice Accessories
Lip glue, LECA, collars, support plates and render for Isokern pumice chimneys. Every pumice joint is sealed with lip glue.
Which pumice accessories do I need?
Most pumice chimney builds need the same core items. Choose by job:
Lip Glue 5kg
Joint sealant for pumice, sealed to 1000°C.About 16 joints per bag on a 150mm liner.
ViewLECA 50 litre bag
Light expanded clay aggregate, 20kg bag.Fills the void with at least 15mm around a pumice liner.
ViewSteel collars
150mm to 350mm internal diameter.Restores the rebated joint when a liner is cut to length on site.
ViewSupport plates
For 150mm, and for 175mm and 200mm blocks.Sits in the support block to carry a flue liner from the stove.
ViewChimney Notice Plate
Identification plate for the finished chimney.Required on completed installations under the Building Regulations.
ViewCollars and support plates by flue size
| Flue (ID) | Steel collar | Support plate |
|---|---|---|
| 150mm | 150mm collar | 150mm plate |
| 175mm | 175mm collar | 175/200mm plate |
| 200mm | 200mm collar | 175/200mm plate |
| 225mm | 225mm collar | – |
| 250mm | 250mm collar | – |
| 300mm | 300mm collar | – |
| 350mm | 350mm collar | – |
Collars are only needed where a liner has been cut. Support plates suit the matching Isokern support block.
Other parts in this section
- Firebricks:25mm and 50mm buff firebricks, 230 × 114mm, rated to 1100°C, for lining firechests and open-fire chambers.
- DM stainless wall tie: ties an external DM chimney to the structure every 1.5m, two per casing, with an extra two at roof level.
- Standard firechest: a pumice open-fire chamber with a 690 × 660mm opening.
- 450mm Milner fireback: a scored clay fireback for 450mm fire openings.
Work out bag quantities with the LECA and lip glue calculator.
Technical downloads
Pumice accessories FAQs
What is lip glue used for?
Isokern lip glue seals the rebated joints in pumice liners, DM flue blocks and casings, giving a gas-tight seal up to 1000°C.
How many joints does a bag of lip glue seal?
A 5kg bag seals approximately 16 joints on a 150mm liner. Larger flues use more per joint.
Why is LECA needed around a pumice liner?
LECA fills the void between the liner and the masonry, with a minimum 15mm surround, for insulation and stability.
When do I need a steel collar?
Only when a liner is cut to length on site. The collar restores the rebated joint so it can be sealed with lip glue.
How often are DM wall ties fitted?
Every 1.5m, two per casing, with an extra two at roof level.
Need help choosing your pumice accessories?
Speak to our Isokern team on 0113 322 5187 or email [email protected]. We can check sizes, flue requirements and what to order.
Isokern is made by Schiedel; we are not the manufacturer.


Pallet
















