300mm (12″) ID Pumice Liner

300mm is the 12 inch nominal size, for a medium to large open fire or a double-sided fire.

9  Products


Which 300mm liner parts do I need?

Rebated volcanic pumice, lip-glued, with LECA around the liner. Check the fire opening before you settle on 300mm. A gather or a Magnum firechest may set the flue size for you.

Specification: 300mm (12 inch) internal diameter, 360mm outside diameter, 600mm section length, approx. 19kg per section (Isokern price list). Certified by Schiedel to EN 1857 (T600 N2 D 3 G). Suitable for all fuel types, but not for condensing appliances.

Stainless Steel Adaptor 300mm i/d

Connects the stove pipe to the liner.

View

300mm i/d Liner Support Block

Base of the liner run at the appliance connection.

View

300mm i/d 600mm High Rebated Liner

The flue section; joints sealed with lip glue.

View

Lip Glue 5kg

Seals every pumice-to-pumice joint, about 2mm thick.

View

Light Expanded Clay Aggregate (50L Bag)

Insulation between the liners and the masonry, minimum 15mm.

View

15°

300mm 15°, 30° and 45° bends.What it is for: Offsets: up to two offsets (four bends), no more than 45° from vertical

View

Steel Collar for 300mm i/d

Required with lip glue on any cut joint.

View

Installation points from Schiedel

  • Install the liners socket uppermost and seal every joint with Isokern lip glue, about 2mm thick, removing any excess.
  • Surround the liners with at least 100mm of brick, block or stone, with a minimum 15mm of LECA mixed 20:1 with OPC cement in between.
  • Support any bends and backfill them with the LECA mix.
  • Keep combustible materials 200mm from the inner surface of the liner, or 40mm from the outside of the masonry chimney.
  • Terminate the chimney at the correct height under Approved Document J, then test it and fix the chimney notice plate in the dwelling.

The flue size is set by the appliance, so always follow the stove or fire manufacturer's instructions and Approved Document J.

Building to a standard height from 4.8m to 9.0m? A 300mm liner pack brings the liners, lip glue, LECA and a chimney notice plate together; connection parts are chosen separately.

Compare every size on the pumice flue liners page, or read how Isokern pumice flue liners work.

300mm pumice liner parts FAQs

Can I use a smaller liner than the stove outlet?

No. Schiedel states the pumice flue must not be smaller than the spigot diameter of the appliance. The flue size is set by the appliance manufacturer.

Can a 300mm pumice flue serve a pellet, biomass or condensing appliance?

No. Schiedel states pumice is suitable only for dry chimneys, so it cannot be used with condensing appliances, including pellet and biomass.

Do I need a chimney pot?

Not necessarily. Schiedel says a pot or terminal is not essential, but it can be fitted for appearance or to help keep rain and birds out. We list 300mm pots in terracotta and buff on the chimney pots page.

How is a 300mm pumice flue swept?

At least twice a year, before and after the heating season, with a 300mm medium-density polypropylene brush. Steel brushes must not be used on pumice flues.

Is there an open-fire gather for 300mm liners?

Yes, the C18 concrete gather. Schiedel gives a minimum chimney height of 4.5m from the top of the fire opening.

Need help choosing your 300mm pumice liner parts?

Speak to our Isokern team on 0113 322 5187 or email [email protected]. We can check sizes, flue requirements and what to order.

Isokern is made by Schiedel; we are not the manufacturer.