Isokern 225mm i/d 30° Bend - Isokern

Isoken Pumice Liner Bend

Isokern 225mm i/d 30° Bend
Isokern

The Isokern 225mm internal diameter 30° bend for small open-fire liner routing.

This pumice liner bend supports flue up to 225mm. It maintains minimum 15mm insulation gap by builder with brickwork or blockwork. Pumice offers high insulation performance maintenance and lightweight long life.

  • Internal diameter: 225mm
  • Bend angle: 30°
  • Material: Pumice construction
  • Insulation: Requires minimum 15mm by builder using brickwork or blockwork
  • Compliance: CE certified to EN 1857

This pumice liner bend is available for order and fits small open-fire adjustments.

.....Read more

The Isokern 225mm internal diameter 30° bend for small open-fire liner routing.

This pumice liner bend supports flue up to 225mm. It maintains minimum 15mm insulation gap by builder with brickwork or blockwork. Pumice offers high insulation performance maintenance and lightweight long life.

  • Internal diameter: 225mm
  • Bend angle: 30°
  • Material: Pumice construction
  • Insulation: Requires minimum 15mm by builder using brickwork or blockwork
  • Compliance: CE certified to EN 1857

This pumice liner bend is available for order and fits small open-fire adjustments.

Read less

SKU 127707
£104.00 Inc VAT
£86.67 ex VAT
Earn0
reward points


Isoken Pumice Liner Bend

Send this to a friend

Isokern 225mm i/d 30° Bend


Product Reviews

Be the first to review this product.

Leave a Review

Product Q&A's

Please feel free to ask any related questions, and we strive to give you the most accurate answer.

1 question

Lesley Irvine asked on :

Maybe a silly question - My builder says we have to have a bend in the chimney to make it draw, but this would not work with the planed route above as we need it straight- do you have to have bends in a chimney?

Answer:

No its not a silly question as we are asked this alot (we are told this by many builders!) - A Chimney / flue system generally performs better the straighter it is vertically, this keeps the friction of the gasses to the flue liner to a minimum and therefore keeps performace maximised, this is  due to less resisitance compared to a bend in the flue which also then increases turbulance. So in short the straighter the flue the better the performance. Traditionally you would install a set of bends on the flue to move the flue route over for the bedroom fire above, which they would try to centralise.

Votes: 3471 up, 0 down