Isokern Configurator: Design Your Chimney Online

The Isokern Configurator lets you design an Isokern chimney in your browser. Choose a pumice liner or Double Module system, a stove or an open fire, your height and any offset, and it draws your chimney to scale with a full parts list, weights, Leca and lip glue. Download the drawing or your technical pack as a PDF, then add every part to your basket in one go.

It's free and you don't need an account.

Drawings and packs are indicative only and not for construction. Prices and stock are shown in your basket. Need a hand? Call us on 0113 322 5187 or contact us.

What the Isokern Configurator does

  • Draws your chimney to scale on an A3 sheet, with labels, heights and a plan view.
  • Lists every part with its product code, quantity and weight.
  • Works out the Leca and lip glue you need.
  • Sizes an open-fire flue from your fire opening, using the 15% rule.
  • Adds offsets with 15°, 30° or 45° bends, or Double Module offset blocks.
  • Lets you download the drawing (PDF) and a full technical pack (PDF).
  • Adds every part to your basket in one click.
The Isokern Configurator showing the options for a 200mm pumice liner chimney to a stove, the chimney drawing, the parts list with weights and the height summary
The configurator set up for a 200mm pumice liner chimney, 6m, to a stove.

How it works

  1. Choose your system. Press Pumice liner or Double Module above the configurator.
  2. Choose a stove or an open fire. For a stove, pick your flue size. For an open fire, enter your fire opening or pick a flue size, then choose a gather or firechest.
  3. Set your chimney. Enter the height, add an offset if you need one, and choose your void and pot colour (or, for Double Module, your capping and chimney top).
  4. Press Update drawing. Your drawing, parts list, weights and height summary update straight away.
  5. Download or buy. Download the drawing or your technical pack as a PDF, or press Add these parts to basket.

Pumice liner or Double Module?

The configurator covers both Isokern chimney systems. Switch between them with the buttons above the configurator.

Pumice linerDouble Module (DM)
What it isPumice flue liners built inside a masonry chimney or void, surrounded by LecaA complete pumice chimney with an outer casing and flue block in one, in DM36, DM44 and DM54
Flue sizes in the configurator125mm to 300mm for a stove; 200mm to 350mm for an open fireDM36: 125mm (with adaptor) and 150mm
DM44: 180mm and 200mm
DM54: 300mm and 345mm
Stove or open fireBothDM36: stove
DM44 and DM54: stove or open fire
Offsets15°, 30° or 45° bendsOffset blocks (30°)
Top of the chimneyChimney pot and top guardCapping for render or brickwork, with corbel options, and a chimney pot or top ring and raincap
ShopPumice liners and liner packsDouble Module: DM36, DM44, DM54

Stove or open fire

Connecting a stove

With a pumice liner you can bring the stove flue pipe up into the support block, or into a 45° T liner.

  • Into the support block: the stove flue pipe slides over the stainless adaptor on the support block spigot.
  • Into a 45° T liner (150mm, 175mm and 200mm): the T liner sits on an upper access block, with a second access block inverted below it on the hearth. The opening between the two blocks takes the double soot door (265 x 395mm) and the insulated plug. You can add liners between the T liner and the soot door, and the configurator adds the T liner, access blocks, soot door and plug to your parts list.
Detail from an Isokern Configurator drawing showing how the stainless adaptor fits over the support block spigot, with the stove flue pipe sliding over the adaptor outlet
Detail: the stainless adaptor on the support block spigot of a 200mm liner.
Isokern Configurator drawing of a 150mm pumice liner stove connection through a 45 degree T liner, with two rebated access blocks, the double soot door and the insulated plug at the base
A stove connected through a 150mm 45° T liner, with the two access blocks, double soot door and insulated plug below.

Sizing an open fire from the opening

Building regulations guidance says the flue area should be at least 15% of the fire opening. Choose Enter the fire opening size and the configurator picks the smallest flue that meets this, from 200mm, 225mm, 250mm, 300mm and 350mm. You can choose a bigger flue but not a smaller one. For example, a 550 x 500mm opening needs at least a 250mm flue, so the configurator offers the C17 gather.

Gathers and firechests start at 200mm, so an open fire always uses a 200mm flue or larger. A Magnum firechest has its own opening, so the configurator sizes from that. For Double Module, it offers DM44 (200mm) or DM54 (345mm), whichever suits your opening.

Gathers and firechests

Gather or firechestFlueNotes
C16 concrete gather200mm or 225mmCode 130699
C17 concrete gather250mmCode 131200
C18 concrete gather300mmCode 131201
Pumice gather on the Standard Firechest225mmPumice liner; the Standard Firechest with the DM44 pumice gather is used for DM44
900 and 1150 Manor gathers350mmCentre or offset hole
Magnum 500 firechest200mmOwn opening: 510 x 540mm
Magnum 950 firechest350mmOwn opening: 990 x 960mm
Magnum 1100 firechest350mmOwn opening: 1130 x 960mm
Magnum 1200 firechest350mmOwn opening: 1246 x 960mm
Isokern Configurator drawing of a 6m, 200mm pumice liner chimney for an open fire on a C16 concrete gather
An open fire on a C16 concrete gather with a 6m, 200mm liner.

Offsets and bends

Enter the offset you need and where it starts. On a pumice liner the configurator uses 15°, 30° or 45° bends and works out the liners between them. On Double Module it uses offset blocks and draws each one stepped across the block below, so you can see that every block is supported. For example, two 86mm offset blocks on DM54 give a 172mm offset.

Isokern Configurator drawing of a 7.2m, 200mm pumice liner chimney to a stove with a 300mm offset made with 30 degree bends, with its bill of materials, Leca and lip glue and height summary
A 7.2m, 200mm liner chimney with a 300mm offset on 30° bends. The parts list, Leca, lip glue and heights run down the right.
Isokern Configurator drawing of a DM54 Double Module 300mm chimney, 7.2m, with a 172mm offset from two 86mm offset blocks and a brick stack with corbel
DM54, 300mm, 7.2m with a 172mm offset from two 86mm offset blocks and a brick stack on a corbel.

Void, Leca and lip glue

  • The void around a pumice liner needs at least 15mm of Leca on each side, so the smallest void is the liner's outside diameter plus 30mm. For a 200mm liner (250mm outside) that is 280 x 280mm.
  • Choose a standard void (235 x 235mm up to 750 x 750mm) or enter your own size. If it's too small for your liner, the configurator moves you up to the next standard void and tells you.
  • Leca is worked out from your void and liner and listed in 50 litre bags.
  • Lip glue is worked out from the number of joints, plus one extra for luck.

Prefer to work it out separately? Try the Leca and lip glue calculator.

Weights and the parts list

Every part is listed with its product code, quantity and weight, with a total for the chimney. Weights are the published unit weights multiplied by the quantity. If a part has no published weight it is named under the total, and the total is marked approximate when it includes Leca. For example, a 6m, 200mm liner chimney to a stove comes to about 330kg including 9 bags of Leca.

Isokern Configurator parts list with quantities, product codes and weights in kilograms for an open fire chimney on a C16 gather
The parts list shows quantities, product codes and weights.
Isokern Configurator drawing of a DM44 Double Module 200mm chimney, 6m, for an open fire on the Standard Firechest with the DM44 pumice gather and a rendered stack
DM44, 200mm, 6m, for an open fire on the Standard Firechest with the DM44 pumice gather.

Download your drawing and technical pack

  • Download this drawing (PDF): your chimney on one A3 sheet with its parts list and heights.
  • Get your technical pack (PDF): your drawing with supporting sheets on joints, connections, terminations and more.
  • Add these parts to basket: adds every part on your list to your basket.

Isokern CAD downloads

Download Isokern drawings for your project as PDF or DXF. Filter by range, type or size, or search by name or product code.

DrawingRangeDownload
Installation: 150mm liner, range cooker, internal chimneyPumice linerPDF · DXF
Installation: 150mm liner, stove connecting at 45 degreesPumice linerPDF · DXF
Installation: 150mm liner, stove, internal chimneyPumice linerPDF · DXF
Installation: 150mm liner, stove, internal chimney (alternative)Pumice linerPDF · DXF
Installation: 175mm liner, stove, internal chimney (alternative)Pumice linerPDF · DXF
Installation: 200mm liner, inset fire, internal chimneyPumice linerPDF · DXF
Installation: 200mm liner, stove connecting at 45 degreesPumice linerPDF · DXF
Installation: 200mm liner, stove, external chimneyPumice linerPDF · DXF
Installation: 200mm liner, stove, internal chimneyPumice linerPDF · DXF
Installation: 200mm liner, stove, internal chimney (alternative)Pumice linerPDF · DXF
Installation: 200mm liner, stove, side offsetPumice linerPDF · DXF
Installation: 250mm liner, inset fire, internal chimneyPumice linerPDF · DXF
Installation: 350mm liner, 1150 Manor gather, internal brick or block chimneyPumice linerPDF · DXF
Installation: 350mm liner, 900 Manor gather, internal brick or block chimneyPumice linerPDF · DXF
Installation: 350mm liner, inglenook with canopyPumice linerPDF · DXF
Installation: Magnum 1200 firechest, 350mm liner with offset, internal brick chimneyPumice linerPDF · DXF
Installation: Magnum 1100 firechest, external chimneyPumice linerPDF · DXF
Installation: Magnum 1100 firechest, internal chimneyPumice linerPDF · DXF
Installation: Magnum 1200 firechest, external chimneyPumice linerPDF · DXF
Installation: Magnum 1200 firechest, external chimney in timber framePumice linerPDF · DXF
Installation: Magnum 1200 firechest, internal chimneyPumice linerPDF · DXF
Installation: Magnum 950 firechest, external chimney (alternative)Pumice linerPDF · DXF
Installation: Magnum 950 firechest, external chimney in timber framePumice linerPDF · DXF
Installation: Magnum 950 firechest, external chimney, timber framePumice linerPDF · DXF
Installation: Magnum 950 firechest, internal chimneyPumice linerPDF · DXF
Installation: Standard Firechest and pumice gather detailPumice linerPDF · DXF
150mm 45 degree T Liner (126376)Pumice linerPDF · DXF
150mm 90 degree T Liner (126375)Pumice linerPDF · DXF
150mm Collar (126361)Pumice linerPDF · DXF
150mm Liner (126372)Pumice linerPDF · DXF
150mm Support Block (126366)Pumice linerPDF · DXF
175mm 45 degree T Liner (126500)Pumice linerPDF · DXF
175mm Collar (126494)Pumice linerPDF · DXF
175mm Liner (126498)Pumice linerPDF · DXF
175mm Support Block (126483)Pumice linerPDF · DXF
175 and 200mm Access Block (127678)Pumice linerPDF · DXF
200mm 45 degree T Liner (127695)Pumice linerPDF · DXF
200mm Collar (127673)Pumice linerPDF · DXF
200mm Liner (127685)Pumice linerPDF · DXF
200mm Support Block (127340)Pumice linerPDF · DXF
225mm Collar (127705)Pumice linerPDF · DXF
225mm Liner (127715)Pumice linerPDF · DXF
225mm Support Block (130731)Pumice linerPDF · DXF
250mm Collar (128533)Pumice linerPDF · DXF
250mm Liner (128546)Pumice linerPDF · DXF
250mm Support Block (128548)Pumice linerPDF · DXF
300mm Collar (129021)Pumice linerPDF · DXF
300mm Liner (129036)Pumice linerPDF · DXF
350mm Collar (129356)Pumice linerPDF · DXF
350mm Liner (129360)Pumice linerPDF · DXF
400mm Liner (129567)Pumice linerPDF · DXF
150mm 15 degree Bend (126364)Pumice linerPDF · DXF
150mm 30 degree Bend (126365)Pumice linerPDF · DXF
150mm 45 degree Bend (126367)Pumice linerPDF · DXF
175mm 15 degree Bend (126495)Pumice linerPDF · DXF
175mm 30 degree Bend (126496)Pumice linerPDF · DXF
175mm 45 degree Bend (126497)Pumice linerPDF · DXF
175mm bend offset chartPumice linerPDF · DXF
200mm 15 degree Bend (127679)Pumice linerPDF · DXF
200mm 30 degree bend (127680)Pumice linerPDF · DXF
200mm 45 degree Bend (127681)Pumice linerPDF · DXF
200mm bend offset chartPumice linerPDF · DXF
225mm 15 degree Bend (127706)Pumice linerPDF · DXF
225mm 30 degree Bend (127707)Pumice linerPDF · DXF
225mm 45 degree Bend (127708)Pumice linerPDF · DXF
225mm bend offset chartPumice linerPDF · DXF
250mm 15 degree Bend (128542)Pumice linerPDF · DXF
250mm 30 degree Bend (128531)Pumice linerPDF · DXF
250mm 45 degree bend (128532)Pumice linerPDF · DXF
250mm bend offset chartPumice linerPDF · DXF
300mm 15 degree Bend (129015)Pumice linerPDF · DXF
300mm 30 degree Bend (129016)Pumice linerPDF · DXF
300mm bend offset chartPumice linerPDF · DXF
350mm 15 degree Bend (129354)Pumice linerPDF · DXF
350mm 30 degree Bend (129355)Pumice linerPDF · DXF
350mm 45Deg Bend (131820)Pumice linerPDF · DXF
350mm bend offset chartPumice linerPDF · DXF
400mm 15 degree Bend (10831)Pumice linerPDF · DXF
400mm 30 degree Bend (129563)Pumice linerPDF · DXF
Installation: DM36 150mm, offset above the support blockDM36PDF · DXF
Installation: DM36 150mm, stove, internal stackDM36PDF · DXF
DM36 45 degree Kit (130709)DM36PDF · DXF
DM36 Access Casing (130712)DM36PDF · DXF
DM36 Access Flue Block (126368)DM36PDF · DXF
DM36 Brickwork Capping (130711)DM36PDF · DXF
DM36 Casing and Soot Door (130713)DM36PDF · DXF
DM36 Corbel (130715)DM36PDF · DXF
DM36 Flue Block (126369)DM36PDF · DXF
DM36 Offset Block (126378)DM36PDF · DXF
DM36 Outer Casing (130714)DM36PDF · DXF
DM36 Rendered Capping (130710)DM36PDF · DXF
DM36 Starter Flue Block (126363)DM36PDF · DXF
DM36 Support Block (130716)DM36PDF · DXF
Installation: DM44 180mm, stoveDM44PDF · DXF
Installation: DM44 180mm, stove, internal stackDM44PDF · DXF
Installation: DM44 200mm, range cooker on a cast slabDM44PDF · DXF
Installation: DM44 200mm, stove on a cast slabDM44PDF · DXF
Installation: DM44 200mm, stove, internal stackDM44PDF · DXF
Installation: DM44, Magnum 500 firechest, internal brick stackDM44PDF · DXF
Installation: DM44, Standard Firechest, external brick stack (plan)DM44PDF · DXF
Installation: DM44, Standard Firechest, external brick stack, timber frame (plan)DM44PDF · DXF
Installation: DM44, Standard Firechest, internal brick stackDM44PDF · DXF
Installation: DM44, Standard Firechest, internal rendered stack with offsetDM44PDF · DXF
Installation: DM44, open fire, timber frame, internal brick stackDM44PDF · DXF
Installation: DM44, open fire, timber frame, internal brick stack (option 2)DM44PDF · DXF
Installation: DM44, open fire, timber frame, internal rendered stackDM44PDF · DXF
Installation: DM44, stove, external brick stack (plan)DM44PDF · DXF
Installation: DM44, stove, external rendered stackDM44PDF · DXF
Installation: Standard Firechest and DM44 pumice gatherDM44PDF · DXF
DM44 180mm Access Block (130717)DM44PDF · DXF
DM44 180mm Offset Block 100mm High (131810)DM44PDF · DXF
DM44 180mm Offset Block 150mm High (130718)DM44PDF · DXF
DM44 180mm Starter Flue Block (130720)DM44PDF · DXF
DM44 180mm Support Block (130721)DM44PDF · DXF
DM44 200mm Flue Block (127683)DM44PDF · DXF
DM44 200mm Offset Block 100mm High (127686)DM44PDF · DXF
DM44 200mm Starter Flue Block (127684)DM44PDF · DXF
DM44 200mm Support Block (130730)DM44PDF · DXF
DM44 Brickwork Capping (130724)DM44PDF · DXF
DM44 Casing and Soot Door (130726)DM44PDF · DXF
DM44 Offset Corbel (130235)DM44PDF · DXF
DM44 Outer casing (130727)DM44PDF · DXF
DM44 T Corbel (130818)DM44PDF · DXF
Installation: DM54 with canopyDM54PDF · DXF
Installation: DM54, Magnum 1200 firechest, internal brick stackDM54PDF · DXF
Installation: DM54, Magnum 1200 firechest, internal rendered stackDM54PDF · DXF
Installation: DM54, Magnum 950 firechest, external brick-clad stackDM54PDF · DXF
DM54 300mm Flue Block (129033)DM54PDF · DXF
DM54 300mm Offset block 150mm High (129038)DM54PDF · DXF
DM54 300mm Starter Flue Block (129031)DM54PDF · DXF
DM54 350mm Flue Block (129094)DM54PDF · DXF
DM54 350mm Offset Block 150mm High (129092)DM54PDF · DXF
DM54 350mm Starter Flue block (129093)DM54PDF · DXF
DM54 Brickwork capping (130734)DM54PDF · DXF
DM54 Outer Casing (130708)DM54PDF · DXF
DM54 Rendered capping (130733)DM54PDF · DXF
Installation: Brick-clad stack detailDouble ModulePDF · DXF
Installation: Rendered stack detailDouble ModulePDF · DXF
DM soot door (50109)Double ModulePDF · DXF
C16 concrete gather (200 and 225mm)GathersPDF · DXF
C18 concrete gather (300mm)GathersPDF · DXF
900 Manor gatherGathersPDF · DXF
Magnum 500 firechestFirechestsPDF · DXF

Download a whole set (ZIP, PDF and DXF)

Drawings are indicative only. Please check with us before construction. More downloads on our CAD files page.

Frequently asked questions

Is the Isokern Configurator free to use?

Yes. Designing your chimney, downloading the drawing PDF and the technical pack PDF are all free, and you don't need an account.

Do I need an account to add the parts to my basket?

No. You can add the parts from your drawing to your basket without signing in. Prices and stock are shown in your basket.

Which Isokern systems does the configurator cover?

Isokern pumice liners from 125mm to 350mm and the Isokern Double Module chimney in DM36, DM44 and DM54. Use the Pumice liner and Double Module buttons above the configurator to switch between them.

Can it size the flue for an open fire?

Yes. Enter your fire opening and the configurator picks the smallest flue whose area is at least 15% of the opening, then offers the gathers that suit it. You can always choose a bigger flue. A Magnum firechest has its own opening, so the configurator uses that.

Which gathers and firechests can I choose?

For pumice liners: the C16, C17 and C18 concrete gathers, the pumice gather on the Standard Firechest for 225mm liners, the 900 and 1150 Manor gathers with a centre or offset hole, and the Magnum 500, 950, 1100 and 1200 firechests. For Double Module: the Standard Firechest with the DM44 pumice gather, or a Magnum firechest.

Can I connect my stove through a T liner?

Yes, on 150mm, 175mm and 200mm liners. Choose “Flue pipe into a 45° T liner”. The drawing shows the T liner above two access blocks, with the double soot door and insulated plug in the opening between them, and adds them to the parts list.

Does it work out Leca and lip glue?

Yes. Leca is calculated from your void size and liner, in 50 litre bags, and lip glue from the number of joints, with one extra tub for luck. If your void is smaller than the liner needs, the configurator moves you up to the next standard void and tells you.

How heavy will my chimney be?

The parts list shows the weight of each line and a total, worked out from the published unit weights. Where a part has no published weight it is named under the total so you know it isn't included.

Can I add offsets?

Yes. Pumice liners can be offset with 15°, 30° or 45° bends. Double Module chimneys use offset blocks, which the drawing shows stepped across each other so every block sits on the one below.

Can I use the drawing for building control?

The drawings are indicative only and not for construction. They are a good starting point for your builder, architect or building control, but please check the details with us and your installer before you build.

More Isokern tools and guides

Shop pumice liner packsShop Double Module

Please note: drawings and packs from the Isokern Configurator are indicative only and not for construction. Please check your design with us and your installer, and follow building regulations. Questions? Call 0113 322 5187 or email [email protected].